Transformer differential protection setting calculation pdf

A t60 percent differential element per unit value refers to setting scaled to the. Transformer differential protection schemes are ubiquitous to. The differential protection and setting calculation of the. In a power transformer protection application the second turnpoint 2 is normally chosen in the range 1. Protection selectivity is partly considered in this report, and could be also revaluated. In differential protection applications, ref542 plus is to have at least six ct inputs.

Omicron cmc256 or 356 test equipment or any equivalent to be used. However the protection should not trip, since the fault is external. Accurate setting of transformer differential protection relay is of utmost. Since differential protection is the primary method of transformer protection. Transformer differential protection scheme works by using two separate quantities. Micom p63x required data ratings of the power and current transformers mva voltage ratio rated voltage in kv hv side rated voltage in kv lv side vector group ct ratio hv side ct hv side vector group ct ratio lv side ct lv side vector group minimum tap. Sample calculationfordifferentialrelays slideshare. Low impedance differential protection relay settings for. Restricted ground fault protection can be a low impedance differential function or a high impedance differential function. The break 1 setting is based on the previously defined pu value of the full load transformer current. The present document introduces the setting calculation for the differential. The first group including t1,t2 and t3 is connected to the three phase current transformers on the highvoltage side and the second group including t4, t5 and t6.

Aiming at the special winding connection of the newtype converting transformer, its connecting scheme of differential protection is proposed based on the establishment of the current transform equations. Parameterize threephase transformer protected object assign the measuring locations on the main protected object example. May 15, 2018 generally differential protection is provided in the electrical power transformer rated more than 5mva. Current differential line protection setting consideration. A transformer has a turns ratio so the current in is not really equal to the current out. Jul 07, 2019 differential protective relay is a protective relay that functions on a percentage or phase angle or other quantitative difference of two currents. Transformer differential protection, while a simple concept, is often misunderstood. Pdf optimizing differential protection settings for power. The differential protection and setting calculation of the newtype converter transformer abstract. Principles of differential relaying my protection guide. Faults close to the neutral produces lesser fault current as shown by the current distribution curve. Ret670 transformer protection substation automation.

Jul 09, 2018 this video outlines the basic principles behind differential protection and is a sample of the full 2. By using modern numerical technology, it is now possible to make differential protection relay 87t, which can properly calculate differential currents for any power transformer, regardless of its. Detailed calculations of differential relay for meeting operational requirement and preventing unwanted tripping on the account of harmonics. While setting parameters will differ depending on the type of current differential relay, the setting principles and system conditions to consider remain largely the same.

Mib202 relay, which can be used to operate for internal faults, like. Optimizing differential protection settings for power. T60 percent differential calculations 2 ge power management it is important for the user to understand the slope 1 and 2 percentage settings and the minimum pickup, break 1, and break 2 perunit values. How to test a transformer differential relay slope, high sets. It helps you to shape up your technical skills in your. Protection systems applied to these may be broadly classified as unit and nonunit protection systems. Percentage restrained differential, percentage of what.

After presenting a definition of unit protection, the principle introduction. Differential relaying provides selectivity by providing a zone of protection with a circuit of interconnected cts. Transformer damage differential and overcurrent protection do not provide adequate protection for wyeconnected windings with grounded neutrals. Abstract the second harmonic inrush restraint function of transformer differential relays maintains security of the differential protection during transformer inrush events. The typical setpoint for the second harmonic restraint is the relay manufacturers default. Sel487e transformer differential relay threephase transformer protection, automation, and control system major features and benefits the sel487e transformer differential relay provides threephase differential protection for transformer applications with up to five threephase restraint current inputs.

It is a static device, totally enclosed and usually oil immersed, and. Diff bias settings calculation transformer power engineering. Sel787 transformer differential protection differential pickup. The restricted ground fault function can be used to provide differential protection for such. Transformer protection application guide this guide focuses primarily on application of protective relays for the protection of power transformers, with an emphasis on the most prevalent protection schemes and transformers. Index terms current differential protection, power transformer, protection relay, single phase i. Relay setting calculation free download as word doc.

Feb 16, 2017 percentage differential restraint settings harmonic blocking individual or common settings effect of residual flux transformer energization inrush current current transformer ct. Explain challenges of transformer differential protection understand need for tap, phase, and zerosequence compensation and how they work understand how transformer differential relays are made secure for inrush and overexcitation transformer differential protection presentation objectives. Unit ct value a t60 percent differential element per unit value refers to setting scaled to the identified unit ct. Medium voltage products technical guide protection criteria. Transformer differential relay highset differential current setting i diff i diff must be greater than maximum inrush current about 15 time transformer rating current harmonic stabilization inrush restraint ratio 2nd harmonic 12% i 2fni fn activate crossblock function relay setting criteria. Relay manufacturers use a variety of calculations like the maximum of the winding currents or the average of the currents. Tutorial on protection of three singlephase transformers. The restricted ground fault function can be used to provide differential protection for such ground faults, down to faults at 5% of the transformer winding. The differential current due to the transformer and its accessories measurement ct, onload tap changer and auxiliary winding is also higher than in normal operation, so the ids set point is exceeded. Differential protection scheme basic and 5mva transformer. May 15, 2018 differential protection scheme basic and 5mva transformer oltc protection calculation published on may. It is a static device, totally enclosed and usually oil immersed, and therefore the fault occurs on them are usually rare.

When a high external fault occurs, a high through current circulates. The focus of this paper is percentage restrained differential protection as applied to a power transformer. This video outlines the basic principles behind differential protection and is a sample of the full 2. Transformer differential protection scheme with internal faults detection algorithm using second harmonics restrain and fifth harmonics blocking logic. Differential protection scheme basic and 5mva transformer oltc protection calculation. This paper describes how to provide universal, current based, differential protection for any threephase power transformer, including phaseshifting transformers with variable phase angle shift. The differential protection is designed to protect power transformers or highvoltage motors. Current transformers application calculation of transformer differential relay setting relay busbar protection abb earth busbar calculation rk 646 differential relay calculation of transformer differential relay relay rd3 diode unit rloe 100 text. These differences are a direct result of three characteristics or a transformer. Transformer differential protection setting calculation. Factors to be considered while setting a differential relay 11. To calculate the secondary current equal to one per unit, the following. Beyond the nameplate selecting transformer compensation. Percentage differential restraint settings harmonic blocking individual or common settings effect of residual flux transformer energization inrush current current transformer ct.

Optimizing differential protection settings for power transformers. Principles of differential relaying current balance high impedance determine worst case throughfault current. Pdf easy method for testing transformer differential relays. These challenges include current magnitude mismatch, transformer phase angle shift, zerosequence current removal, unequal current transformer ct. Scribd is the worlds largest social reading and publishing site. While the basic premise of transformer differential protection is straightforward, numerous features are employed to compensate for challenges presented by. Differential protection of transformer differential relays. Transformer maximum tap change, cable capacitive current, mismatching of cts, no load magnetizing current slope k1 together with its base point counts for current proportional false current due to ct errors about 2025%. Medium voltage products technical guide protection.

Differential protection of a transformer the transformer is one of the major equipment in power system. Mar 30, 2017 sample calculation for differential relays 1. Transformer differential protection voltage disturbance. Get access to premium hvmvlv technical articles, electrical engineering guides, research studies and much more. Percentage restrained differential protection is one of the oldest forms of adaptive protection algorithms. The calculations with illustrative examples apply to twowinding power transformer applications. This is the test procedure for siemens 7ut61 relay iec61850 supported numerical relay. The faults occur in the transformer inside the insulating oil can be detected by buchholz relay. The slope characteristic can provide high sensitivity when low levels of current are. The differential protection of transformer has many advantages over other schemes of protection. This technical report refers to the electrical protections of all 2kv switchgear. Differential relay setting calculations of the power transformer based on typical power transformer data as mentioned below.

Cts having the same ratio are installed in all the connections to the. For transformers the differential protection figure 1 is basically the same as that for a bus but there are certain differences that we will look more closely at. Mar 23, 2016 differential protection setting calculations 87h function is not blocked by any harmonic restraint pickup must be set above first peak of inrush current 87h is used in almost all transformer differentials to overcome restraint of 87t due to ct saturation for high internal transformer faults typical pickup setting is 8 to 12 p. The circuit has an a phase to ground fault on the line, with fault current magnitude of 9000 a. This setting should be larger then the transformer magnetizing current and steady state ct errors during no load conditions.

Id setting depends to the nominal current with considering. Following parameters define differential characteristics. For reliable protection and control of all types of power transformers and reactors. Indication for blocked relay is given with yellow led. Model setting calculations for typical ieds line protection. Transformer differential protection schemes are ubiquitous to almost any power system. Siprotec 7ut6 the siprotec 7ut6 differential protection relays are used for fast and selective fault clearing of shortcircuits in transformers of all voltage levels and also in rotating electric machines like motors and generators, for short lines and busbars. T60 percent differential calculations ge grid solutions online store.

Fault current flowing through saturated ct and associated wiring generates a voltage across the relayrscombination. Relay settings calculations electrical engineering. A setting of 3 times the tap as suggested in the sel 3876 manual can be used. Differential relay sensitivity is inversely proportional to restraint current. S setting is the combination of differential pick up and turning point differential setting. The mib202 is microcontroller based numerical biased differential protection relay with inbuild current amplitude and vector group compensation features and also with instantaneous differential highset element for two winding power transformer and autotransformers. Protection settings calculations for power transformers. These settings may be revaluated during the commissioning, according to actual and measured values. Investigation of recent trippings of power transformer on harmonics in differential relay for taking corrective action to prevent further trippings. Pdf optimizing differential protection settings for. Ret670 optimized for transmission applications ret670 ieds provide customized or preconfigured protection solutions for any type of transformer and shunt reactor application.

Setting procedures are only discussed in a general nature in the material to follow. Practical experience in setting transformer differential. Having a transformer in the zone of protection offers many challenges to the relay setting engineer. Practical experience in setting transformer differential inrush restraint 63 1. Scope this document introduces the application of the threephase differential protection in ref542plus.

230 689 1007 557 1564 595 95 108 1136 1448 711 1165 1002 215 421 94 1396 73 848 152 1570 125 1540 820 1161 1403 1366 618 567 884 539 631 881 721 1150 1526 1453 411 1078 1436 311 358 1467 252 1047 851 667 1018 400